ADHESIVE SYSTEMS INC -- GASKET REMOVER, 8293 -- 8010-00N058029
===================== Product Identification =====================
Product ID:GASKET REMOVER, 8293
MSDS Date:05/26/1992
FSC:8010
NIIN:00N058029
=== Responsible Party ===
Company Name:ADHESIVE SYSTEMS INC
Address:4163 W 166TH ST
City:OAK FORREST
State:IL
ZIP:60452
Country:US
Info Phone Num:708-333-5600
Emergency Phone Num:800-535-5053
CAGE:0RE06
=== Contractor Identification ===
Company Name:ADHESIVE SYSTEMS INC
Address:4163 W 166TH ST
Box:City:OAK FORREST
State:IL
ZIP:60452
Country:US
Phone:708-333-5600
CAGE:0RE06
============= Composition/Information on Ingredients =============
Ingred Name:METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA 313)
(CERCLA)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 90%
OSHA PEL:500 PPM
ACGIH TLV:50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:METHANOL (SARA 313) (CERCLA)
CAS:67-56-1
RTECS #:PC1400000
Fraction by Wt: 9%
OSHA PEL:200 PPM, S
ACGIH TLV:200 PPM;250 STEL, S
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SKIN & EYES:CONTACT IRRITATION.
INHAL:MAY CAUSE NAUSEA, HEADACHE,, DIZZINESS & IRRITATION OF
RESPIRATORY TRACT. CHLOROCARBON MATERIALS HAVE PRODUCED
SENSITIZATION OF MYOCARDIUM TO EPINEPHRINE IN LAB A NIMALS & COULD
HAVE SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE)
MAY BE CONTRAINDICATED(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:IARC MONOGRAPHS,
SUPP, VOL 7, PG 194, 1987:GRP 2B. NTP 7TH ANNUAL RPT ON CARCINS,
1994:ANTIC (SUPDAT)
Effects of Overexposure:HLTH HAZ:EXCEPT FOR LIFE-SUSTAINING USES IN
HUMANS ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INGEST:CALL MD IMMEDIATELY . EYES:FLUSH W/WATER FOR AT LEAST
15 MINUTES - CONTACT MD. SKIN:WASH W/SOAP & WATER. INHAL:PROVIDE
FRESH AIR, OXYGEN OR ARTIFICIAL RESPIRATION AS NEEDED. NOTE TO
MD:TH E USE OF EPINEPHRINE IS CONTRAINDICATED.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:>200F,>93C
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP . COOL SEALED DRUMS W/WATER SPRAY TO LESSEN CHANCE OF
RUPTURE. DIRECT WATER JET WILL (SUPP DATA)
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE . COMBUSTION PRODUCTS ARE VERY TOXIC &
HIGHLY IRRITATING.
================== Accidental Release Measures ==================
Spill Release Procedures:PERMIT ONLY PROPERLY PROTECTED WORKERS IN THE
AREA (I.E. W/EYE OR SKIN PROTECTION & NIOSH/MSHA APPROVED
SELF-CONTAINED BREATHING GEAR). ABSORB SMALL SPILLS W/INERT
MATERIAL. PUMP LARGE SPILLS INTO SAL VAGE TANKS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE DRUMS, WELL SEALED, IN COOL,
DRY, WELL-VENTILATED AREA. EMPTY CONTAINERS ARE HAZARDOUS! OBSERVE
ALL LABEL PRECAUTIONS.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV
RADIATION MAY CAUSE THE FORMATION OF HCL &/OR PHOSGENE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:ABOVE PEL/TLV, USE NIOSH/MSHA APPROVED
RESPIRATOR FOR ORGANIC VAPORS.
Ventilation:LOCAL EXHAUST RECOMMENDED.
Protective Gloves:RESISTANT, PLASTIC OR RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:OTHER PROTECTIVE EQUIPMENT AS NEEDED TO
ELIMINATE SKIN CONTACT. EYEWASH STATION & SAFETY SHOWER SHOULD BE
IN WORK AREA.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:SPREAD BURNING MATERIAL. EXPLAN OF CARCIN:TO BE
CARCINOGEN. ANIMAL:LUNG, LIVER, SALIVARY, MAMMARY GLAND (TUMORS).
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>104F,>40C
Vapor Density:HVR/AIR
Spec Gravity:1.236
Solubility in Water:NIL
Appearance and Odor:THICK, WATER-WHITE LIQUID W/ETHEREAL ODOR.
Percent Volatiles by Volume:99
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, ACIDS, BASES & "WHITE" METALS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:PHOSGENE . HCL & OTHER CHLORINATES.
==================== Disposal Considerations ====================
Waste Disposal Methods:CONTACT FEDERAL, STATE & LOCAL AGENCIES TO
ENSURE COMPLIANCE OF DISPOSAL METHOD W/CURRENT REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.