SPECTRUM CHEMICAL MANUFACTURING CORP -- TETRAHYDROFURAN -- 6810-00N022710
===================== Product Identification ===================== Product ID:TETRAHYDROFURAN MSDS Date:12/06/1989 FSC:6810 NIIN:00N022710 === Responsible Party === Company Name:SPECTRUM CHEMICAL MANUFACTURING CORP Address:14422 S SAN PEDRO ST City:GARDENA State:CA ZIP:90248-9985 Country:US Info Phone Num:213-516-8000 Emergency Phone Num:213-516-8000;800-424-9300(CHEMTREC) CAGE:63415 === Contractor Identification === Company Name:SPECTRUM LABORATORY PRODUCTS INC Address:14422 S SAN PEDRO ST Box:City:GARDENA State:CA ZIP:90248-2027 Country:US Phone:310-516-8000/FAX: 310-516-9843 CAGE:63415 ============= Composition/Information on Ingredients ============= Ingred Name:FURAN, TETRAHYDRO-; (TETRAHYDROFURAN) (SARA III) CAS:109-99-9 RTECS #:LU5950000 Fraction by Wt: >99% OSHA PEL:200 PPM;250 STEL ACGIH TLV:200 PPM;250 STEL EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:OXIDATION INHIBITOR; (PEROXIDATION INHIBITOR) Fraction by Wt: TRACE Ingred Name:SUPDAT:INFO ) ATTACKS SOME PLASTICS, RUBBER. RTECS #:9999999ZZ Ingred Name:EFTS OF OVEREXPOS:CHRONIC:INHAL:ANIMAL EXPOS TO OVER 3000 PPM FOR 20 DAYS EXHIBITED IRRIT OF UPPER RESP TRACT. (ING 5) RTECS #:9999999ZZ Ingred Name:ING 4:LIVER & KIDNEY DMG WAS OBSERVED BUT MAY HAVE BEEN DUE TO IMPURITIES. SKIN:MAY CAUSE IRRIT, DEHYDRATION (ING 6) RTECS #:9999999ZZ Ingred Name:ING 5:& DEFATTING, & SUBSEQUENT DERM. EYE:MAY CAUSE CONJ. INGEST:REPORTED TO CAUSE LIVER & KIDNEY DMG. RTECS #:9999999ZZ Ingred Name:FIRST AID PROC:LIFTING LIDS, UNTIL NO EVIDENCE OF CHEM REMAINS (AT LEAST 15-20 MIN). GET MD ATTN IMMED. (ING 8) RTECS #:9999999ZZ Ingred Name:ING 7:INGEST:IF CONSCIOUS & NOT CONVULSING, INDUCE VOMIT BY GIVING SYRUP OF IPECAC FOLLOWED BY WATER. (IF VOMIT (ING 9) RTECS #:9999999ZZ Ingred Name:ING 8:OCCURS KEEP HEAD BELOW HIPS TO PREVENT ASPIRATION). GASTRIC LAVAGE SHOULD BE PERFORMED BY QUALIFIED MED (ING 10) RTECS #:9999999ZZ Ingred Name:ING 9:PERSONNEL. GET MD ATTN IMMED. NO SPECIFIC ANTIDOTE. TREAT SYMPTOMATICALLY & SUPPORTIVELY. RTECS #:9999999ZZ Ingred Name:SPILL PROC:OR FLARE IN HAZ AREA. EVACUATE AREA. REPORTABLE QTY:1000 LBS. RTECS #:9999999ZZ Ingred Name:OTHER PREC:ADDING INHIBITOR. AVOID CONT W/HEAT, SPARKS, FLAMES/OTHER SOURCES OF IGNIT. VAP MAY BE EXPLOSIVE & (ING 13) RTECS #:9999999ZZ Ingred Name:ING 12:POISONOUS; DO NOT ALLOW UNNEC PERSONNEL IN AREA. DO NOT OVERHEAT CONTRS; CONTRS MAY VIOLENTLY RUPTURE & (ING 14) RTECS #:9999999ZZ Ingred Name:ING 13:TRAVEL CONSIDERABLE DISTANCE IN HEAT OR FIRE. STORE IN ACCORDANCE WITH 29 CFR 1910.106. RTECS #:9999999ZZ ===================== Hazards Identification ===================== LD50 LC50 Mixture:LD50 (ORAL, RAT):2816 MG/KG Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE:INHAL:IRRIT/NARCOTIC. HIGH VAP CONC MAY CAUSE SEV OCCIPITAL HDCH & DULLNESS, MUCOUS MEMBRANE IRRIT, SORE THROAT, COUGHING, NAUS, CNS DEPRESS, FATIGUE, UNCONSCIOUSNESS & POSS ASPHY. IN LAB ANIMAL S CONC ABOVE 25,000 PPM PRODUCED ANESTHESIA, VOMIT, MARKED FALL IN BLOOD PRESS & STRONG RESP (EFTS OF OVEREXPOS) Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZ:STIMULATION. SKIN:ESSENTIALLY NONIRRIT. SKIN ABSORP MAY OCCUR. EYE:VAP MAY CAUSE IRRIT, REDNESS, TEARING & BLURRED VISION. LIQ MAY CAUSE SEV IRRIT/POSS BURNS. INGEST:MAY CAUSE GI IRRIT, SORE THROAT, ABDOMINAL PAIN, NAUS, VOMIT, DIARR & DULLNESS. ASPIR MAY CAUSE SEV LUNG IRRIT & POSS DELAYED CHEM PNEUM.(ING 4) Medical Cond Aggravated by Exposure:PERSONS WITH IMPAIRED LIVER, KIDNEY OR PULMONARY FUNCTION; EYE/SKIN DISORDERS. ALCOHOL MAY ENHANCE TOXIC EFFECTS. ======================= First Aid Measures ======================= First Aid:INHAL:REMOVE FROM EXPOS TO FRESH AIR IMMED. IF BRTHG HAS STOPPED, PERFORM ARTIF RESP. KEEP WARM & AT REST. TREAT SYMPTOMATICALLY & SUPPORTIVELY. GET MD ATTN IMMED. SKIN:REMOVE CONTAM CLTHG & SHOES IMM ED. WASH AFFECTED AREA W/SOAP/MILD DETERGENT & LRG AMTS OF WATER UNTIL NO EVIDENCE OF CHEM REMAINS (APPROX 15-20 MIN). GET MD ATTN IMMED. EYES:WASH IMMED W/LRG AMTS OF WATER/NORMAL SALINE,(ING 7) ===================== Fire Fighting Measures ===================== Flash Point Method:CC Flash Point:6F,-14C Lower Limits:2% Upper Limits:11.8% Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, HALON, WATER SPRAY, FOG OR ALCOHOL FOAM. Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP. MOVE CONTRS FROM FIRE AREA IF POSS. COOL FIRE EXPOS CONTRS W/ WATER FOG. WITHDRAW IMMED IN CASE OF (SUPDAT) Unusual Fire/Explosion Hazard:DANGEROUS WHEN EXPOSED TO HEAT/FLAME. VAP- AIR MIX ARE EXPLOS. VAP ARE HVR/AIR & MAY TRAVEL A CONSIDERABLE DISTANCE TO SOURCE OF IGNIT & FLASH BACK. ================== Accidental Release Measures ================== Spill Release Procedures:SHUT OFF IGNIT SOURCES. STOP LEAK IF W/OUT RISK. USE WATER SPRAY TO REDUCE VAP. FOR SMALL SPILLS, TAKE UP W/SAND/OTHER ABSORB MATL & PLACE INTO CONTRS FOR LATER DISP. FOR LRG SPILLS, DIKE FAR AHEAD OF SPILL FOR LATER DISP. NO SMOKING, FLAME,(ING 11) Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:MEET BONDING & GROUNDING GUIDELINES SPECIFIED IN NFPA 77-1983, REC PRACTICE ON STATIC ELECT. PROT AGAINST PHYSICAL DMG. SEPERATE FROM OXIDIZING MATL. Other Precautions:STORE IN COOL, DARK & WELL VENT AREA, AWAY FROM SOURCES OF HEAT. OUTSIDE/DETACHED STOR IS PREFERABLE. INSIDE STOR SHOULD BE IN STANDARD FLAMM LIQ STOR ROOM/CABINET. PERIODICALLY CHECK FOR PEROXIDE CON TANT & MAINTAIN BELOW 1% BY (ING 12) ============= Exposure Controls/Personal Protection ============= Respiratory Protection:SPECIFIC RESP SELECTED MUST BE BASED ON CONTAM LEV FOUND IN WORK PLACE, MUST NOT EXCEED WORKING LIM OF RESP & BE NIOSH/MSHA APPROVED. FOR MORE INFORMATION CONTACT NEHC . Ventilation:PROVIDE LOCAL EXHAUST OR GENERAL VENTILATION TO MEET EXPOSURE LIMITS. VENTILATION EQUIPMENT MUST BE EXPLOSION PROOF. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:CHEMICAL WORKERS GOGGLES . Other Protective Equipment:EYE WASH FOUNTAIN WITHIN IMMEDIATE WORK AREA FOR EMERGENCY USE. IMPERVIOUS CLOTHING AND EQUIPMENT TO PREVENT CONTACT. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health FIRE FIGHT PROC:RISING SOUND FROM VENT SAFETY DEVICE/ANY DISCOLORATION OF STOR TANK DUE TO FIRE. EXTING ONLY IF FLOW CAN BE STOPPED. EVACUATE TO A RADIUS OF 1500 FT FOR UNCONTROLLABLE FIRES. CONDTNS T O AVOID:TO DRYNESS, AN EXPLOS MAY OCCUR. MATL TO AVOID: TETRAHYDROALYMINATE & OTHERS. CONTACT NEHC FOR MORE (ING 3) ================== Physical/Chemical Properties ================== HCC:F3 Boiling Pt:B.P. Text:153F,67C Melt/Freeze Pt:M.P/F.P Text:-162F,-108C Vapor Pres:145 @ 20C Vapor Density:2.5 Spec Gravity:0.8892 Evaporation Rate & Reference:14.5 (BUTYL ACETATE = 1) Solubility in Water:COMPLETE Appearance and Odor:COLORLESS, VOLATILE, MOBILE LIQUID WITH AN ETHER-LIKE ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES REACTS VIOLENTLY/EXPLOS W/LITHIUM ALUMINUM ALLOYS, STRONG OXIDIZERS, POTASSIUM DIOXIDE, SODIUM (SUPDAT) Stability Condition to Avoid:IF PEROXIDATION IS UNINHIBITED, MAY FORM EXPLOS ORGANIC PEROXIDES WHEN EXPOS TO AIR. IF DISTILLED/EVAPORATED (SUPDAT) Hazardous Decomposition Products:THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE TOXIC COX. Conditions to Avoid Polymerization:MAY POLYMERIZE EXOTHERMICALLY IN CONTACT WITH SOME ACIDS. ==================== Disposal Considerations ==================== Waste Disposal Methods:OBSERVE ALL LOCAL, STATE AND FEDERAL REGULATIONS WHEN STORING OR DISPOSING OF THIS SUBSTANCE. FOR ASSISTANCE, CONTACT DISTRICT DIRECTOR OF ENVIRONMENTAL PROTECTION AGENCY, 40 CFR 262. HAZ WASTE #U213 Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.