ALDON CORPORATION -- MAGNESIUM HYDROXIDE -- 6640-00T718497
===================== Product Identification ===================== Product ID:MAGNESIUM HYDROXIDE MSDS Date:03/12/1990 FSC:6640 NIIN:00T718497 Status Code:A === Responsible Party === Company Name:ALDON CORPORATION Address:1533 W. HENIRETTA RD City:AVON State:NY ZIP:14414 Country:US Info Phone Num:716-226-6177/334-4222 (NIGHT) Emergency Phone Num:716-359-2502 Preparer's Name:ALEXANDER A. PICCINILLI Chemtrec Ind/Phone:(800)424-9300 CAGE:6V042 === Contractor Identification === Company Name:AL-DON CHEMICALS INC Address:1533 W HENRIETTA RD Box:City:AVON State:NY ZIP:14414-9508 Country:US Phone:716-226-6177 CAGE:6V042 Company Name:SCIENCE KIT INC Address:777 E PARK DR Box:City:TONAWANDA State:NY ZIP:14150-6708 Country:US Phone:716-874-6020 Contract Num:MDA414-98-A-0058-0018 CAGE:57020 ============= Composition/Information on Ingredients ============= Ingred Name:MAGNESIUM HYDROXIDE CAS:1309-42-8 RTECS #:OM3570000 = Wt:100. Other REC Limits:NOT PROVIDED. OSHA PEL:NOT PROVIDED. ACGIH TLV:NOT ESTABLISHED. ===================== Hazards Identification ===================== LD50 LC50 Mixture:NOT PROVIDED. Health Hazards Acute and Chronic:EFFECTS OF OVEREXPOSURE: INHALATION: DUST MAY CAUSE IRRITATION TO UPPER RESPIRATORY TRACT. SKIN: MAY CAUSE IRRITATION. INGESTION: LAXATIVE. EYES: NO SPECIFIC HAZARD KNOWN. HOWEVER, ANY MATERIAL THAT CONTACTS THE EYE MAY BE IRRITATING OR CAUSE MECHANICAL INJURY. Explanation of Carcinogenicity:NOT PROVIDED. Effects of Overexposure:INHALATION: DUST MAY CAUSE IRRITATION TO UPPER RESPIRATORY TRACT. SKIN: MAY CAUSE IRRITATION. INGESTION: LAXATIVE. EYES: NO SPECIFIC HAZARD KNOWN. HOWEVER, ANY MATERIAL THAT CONTACTS THE EYE MAY BE I RRITATING OR CAUSE MECHANICAL INJURY. Medical Cond Aggravated by Exposure:NOT PROVIDED. ======================= First Aid Measures ======================= First Aid:INHALATION: REMOVE TO FRESH AIR. IF ILL EFFECTS DEVELOP, GET MEDICAL ATTENTION. SKIN: FLUSH WITH WATER. EYES: FLUSH THOROUGHLY WITH WATER, LIFTING UPPER AND LOWER EYELIDS OCCASIONALLY. IF IRRITATION D EVELOPS OR PERSISTS, GET MEDICAL ATTENTION. INGESTION: GIVE ONE OR TWO GLASSES OF WATER TO DRINK. IF ILL EFFECTS DEVELOP, GET MEDICAL ATTENTION. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. ===================== Fire Fighting Measures ===================== Flash Point:NONFLAMMABLE Lower Limits:NOT RELEVANT Upper Limits:NOT RELEVANT Extinguishing Media:USE ANY MEDIA SUITABLE FOR EXTINGUISHING SUPPORTING FIRE. Fire Fighting Procedures:IN FIRE CONDITIONS, WEAR A NIOSH-APPROVED SELF-CONTAINED BREATHING APPARATUS. Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS DECOMPOSITION PRODUCTS; CAN REACT WITH ACIDS. ================== Accidental Release Measures ================== Spill Release Procedures:AVOID CREATING DUST. SWEEP UP AND PLACE IN A SUITABLE CONTAINER FOR DISPOSAL. WASH SPILL AREA WITH SOAP AND WATER. Neutralizing Agent:NOT PROVIDED. WEAK ACID (HMIS). ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN A COOL, DRY PLACE AWAY FROM ACIDS AND ACID FLAMES. USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER HANDLING. KEEP CONTAINER TIGHTLY CLOSED WHEN NOT IN USE. Other Precautions:READ LABEL ON CONTAINER BEFORE USING. DO NOT WEAR CONTACT LENSES WHEN WORKING WITH CHEMICALS. REMOVE AND WASH CONTAMINATED CLOTHING. FOR LABORATORY USE ONLY. NOT FOR FOOD, DRUG OR HOUSEHOLD USE. KEEP OUT OF REACH OF CHILDREN. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:IF DUSTY CONDITIONS PREVAIL, WORK IN FUME HOOD OR WEAR A NIOSH-APPROVED DUST MASK OR RESPIRATOR. Ventilation:LOCAL EXHAUST AND MECHANICAL EXHAUST FOR DUSTY CONDITION Protective Gloves:RUBBER Eye Protection:CHEMICAL SAFETY GLASSES Other Protective Equipment:EYE WASH STATION, GOGGLES, VENTILATION HOOD, PROPER GLOVES, LAB COAT. Work Hygienic Practices:NOT PROVIDED. Supplemental Safety and Health P/N: 83791-03. ================== Physical/Chemical Properties ================== HCC:N1 NRC/State Lic Num:NOT RELEVANT. Boiling Pt:B.P. Text:DECOMPOSES Melt/Freeze Pt:M.P/F.P Text:DECOMPOSES Decomp Temp:=350.C, 662.F Vapor Pres:NEGLIGIBLE Spec Gravity:2.36 pH:NOT PROVIDED. Viscosity:NOT RELEVANT. Evaporation Rate & Reference:NOT VOLATILE Solubility in Water:INSOLUBLE Appearance and Odor:FINE, WHITE POWDER - NO ODOR Percent Volatiles by Volume:NOT VOLATILE Corrosion Rate:NOT PROVIDED. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES ACID AND ACID FUMES, MALEIC ANYDRIDE, PHOSPHORUS Stability Condition to Avoid:ACID AND ACID FUMES Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY INCLUDE TOXIC FUMES OF MAGNESIUM OXIDES AS FUMES AND DUST. =================== Toxicological Information =================== Toxicological Information:TWA AS MAGNESIUM OXIDE FUME 10 MG/M3 ===================== Ecological Information ===================== Ecological:NOT PROVIDED. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MAY BE SUBJECT TO FEDERAL, STATE OR LOCAL LAWS. THESE DISPOSAL GUIDELINES ARE INTENDED FOR THE DISPOSAL OF CATALOG-SIZE QUANTITIES ONLY. UNCONTAMINATED MATERIAL MAY BE DISPOSED OF IN A SANITARY LANDFILL. =================== MSDS Transport Information =================== Transport Information:NON-REGULATED. ===================== Regulatory Information ===================== SARA Title III Information:NOT PROVIDED. Federal Regulatory Information:NOT PROVIDED. State Regulatory Information:NOT PROVIDED. ======================= Other Information ======================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.