HENKEL SURFACE TECHNOLOGIES -- ALODINE 1201 -- 8030-00-065-0957
=====================  Product Identification  =====================

Product ID:ALODINE 1201
MSDS Date:07/06/1998
FSC:8030
NIIN:00-065-0957
Status Code:A
=== Responsible Party ===
Company Name:HENKEL SURFACE TECHNOLOGIES
Address:32100 STEPHENSON HWY
City:MADISON HEIGHTS
State:MI
ZIP:48071
Country:US
Info Phone Num:248-583-9300
Emergency Phone Num:(800)424-9300
Preparer's Name:HENRY SIMMONS
Chemtrec Ind/Phone:(800)424-9300
CAGE:1N6B3
=== Contractor Identification ===
Company Name:HENKEL SURFACE TECHNOLOGIES
Address:32100 STEPHENSON HWY
Box:City:MADISON HEIGHTS
State:MI
ZIP:48071
Country:US
Phone:248-583-9300
CAGE:1N6B3

=============  Composition/Information on Ingredients  =============

Ingred Name:POTASSIUM FERRICYANIDE
CAS:13746-66-2
RTECS #:LJ8225000
< Wt:1.

Ingred Name:CHROMIC(VI) ACID
CAS:7738-94-5
RTECS #:GB2450000
< Wt:1.
OSHA PEL:SEE TABLE Z-2
ACGIH TLV:0.05 MG/M3
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Ingred Name:HYDROGEN FLUORIDE
CAS:7664-39-3
RTECS #:MW7875000
< Wt:1.
OSHA PEL:SEE TABLE Z-2
ACGIH STEL:C2.6 MG/M3;C3 PPM
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

=====================  Hazards Identification  =====================

Health Hazards Acute and Chronic:DANGER! CORROSIVE! CONTACT WITH THIS
    MATERIAL WILL CAUSE BURNS TO THE SKIN, EYES AND MUCOUS MEMBRANES.
    MAY CAUSE BLINDNESS. CONTACT WITH BROKEN SKIN MAY RESULT IN ULCERS.
    PROLONGED OR REPEATED BREATHI NG MAY CAUSE ULCERATION OF NASAL
    MEMBRANES. FOLLOWING SKIN EXPOSURE TO THIS PRODUCT, THE SENSATION
    OF IRRITATION OR PAIN MAY BE DELAYED. CANCER HAZARD.
Effects of Overexposure:EYE CONTACT-THIS PRODUCT IS SEVERELY IRRITATING
    TO THE EYES AND MAY CAUSE IRREVERSIBLE DAMAGE INCLUDING BURNS AND
    BLINDNESS.	SKIN CONTACT-CONTACT WITH BROKEN SKIN MAY LEAD TO
    FORMATION OF FIRMLY MARG INATED CHROME SORE. PRODUCT CONTAINS
    CHROMIUM, WHICH MAY CAUSE AM ALLERGIC SKIN SENSITIZATION REACTION.
    MASSIVE OVEREXPOSURES MAY LEAD TO KIDNEY FAILURE AND DEATH.
    FOLLOWING SKIN EXPOSURE TO THIS PROD UCT, THE SENSATION OF
    IRRITATION OR PAIN MAY BE DELAYED.	 INGESTION: THIS PRODUCT MAY
    PRODUCES CORROSIVE DAMAGE TO THE GASTROINTESTINAL TRACT IF IT
    SWALLOWED.
Medical Cond Aggravated by Exposure:PRE-EXISTING EYE, SKIN AND
    RESPIRATORY DISORDERS.

=======================  First Aid Measures  =======================

First Aid:EYE CONTACT IN CASE OF CONTACT WITH THE EYES, RINSE
    IMMEDIATELY WITH PLENTY OF WATER FOR 15 MINUTES. AND SEEK IMMEDIATE
    ATTENTION.	SKIN CONTACT- IMMEDIATELY TAKE OF ALL CONTAMINATED
    CLOTHING. FOR SKI N CONTACT. FLUSH WITH LARGE AMOUNTS OF WATER.
    SEEK IMMEDIATE MEDICAL ATTENTION. IF IRRITATION PERSISTS, REPEAT
    FLUSHING AND GET MEDICAL ATTENTION.  INGESTION-IF THE MATERIAL IS
    SWALLOWED, GET IMMEDIAT E MEDICAL ATTENTION OR ADVICE. DO NOT
    INDUCE VOMITING.  INHALATION-IF MIST OF VAPOR OF THIS PRODUCT IS
    INHALED. REMOVE IMMEDIATELY TO FRESH AIR. SEEK MEDICAL ATTENTION IF
    SYMPTOMS DEVELOP OR PERSIST.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE ANY MEDIA SUITABLE FOR SURROUNDING FIRES.
Fire Fighting Procedures:FIREFIGHTER SHOULD WEAR FULL PROTECTIVE
    CLOTHING INCLUDING SELF CONTAINED BREATHING APPARATUS
Unusual Fire/Explosion Hazard:IF EVAPORATED TO DRYNESS, SOLD RESIDUE IS
    AN OXIDIZING AGENT AND MAY CAUSE SPONTANEOUS IGNITION OF COMBUSTION
    MATERIALS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:STOP THE FLOW WITH INERT MATERIAL  WEAR
    APPROPRIATE PROTECTIVE EQUIPMENT AND CLOTHING DURING CLEANUP. 
    ABSORB SPILL WITH INERT MATERIAL. SHOVEL MATERIAL INTO APPROPRIATE
    CONTAINER FOR DISPOSAL. DISPOS E OF COLLECTED MATERIAL ACCORDING TO
    REGULATION.
Neutralizing Agent:OCULAR EXPOSURE TO CORROSIVE FLUORIDE COMPOUNDS HAS
    BEEN TREATED WITH ISOTONIC SODIUM CHLORIDE OR MAGNESIUM CHLO

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT GET THIS MATERIAL IN YOUR EYES,
    OR ON YOUR CLOTHING. DO NOT INHALE VAPORS OR MISTS OF THIS PRODUCT.
    WASH THOROUGHLY AFTER HANDLING. FOR INDUSTRIAL USE ONLY. CLOTHING
    OR OTHER MATERIAL WET WITH	THIS PRODUCT ARE ALLOWED TO DRY MAY
    BECOME FLAMMABLE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF VENTILATION IS NOT SUFFICIENT TO EFFECTIVELY
    PREVENT BUILDUP OF DUST, APPROPRIATE NIOSH/MSHA RESPIRATORY
    PROTECTION MUST BE PROVIDED
Ventilation:VENTILATION SHOULD EFFECTIVELY REMOVE AND PREVENT BUILDUP
    OF ANY VAPOR OR MIST GENERATED FROM THE HANDLING OF THIS PRODUCT.
Protective Gloves:USE IMPERVIOUS GLOVES.
Eye Protection:WEAR CHEMICAL GOGGLES; FACE SHIELD (IF SPLASHING IS
    POSSIBLE)
Other Protective Equipment:EYE WASH FOUNTAIN AND EMERGENCY SHOWERS ARE
    RECOMMENDED.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Boiling Pt:=100.C, 212.F
Spec Gravity:1.0 -1.1
Solubility in Water:COMPLETE
Appearance and Odor:AMBER LIQUID

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH ORGANIC MATERIAL, OILS, GREASE, AND ANY OXIDIZABLE
    MATERIAL. THIS PRODUCT MAY REACT WITH STRONG ALKALIES.
Stability Condition to Avoid:NONE EXPECTED
Hazardous Decomposition Products:MAY LIBERATE HYDROGEN FLUORIDE, WHEN
    HEATED TO DECOMPOSITION OR ON CONTACT WITH STRONG ACIDS POTASSIUM
    FERRICYANIDE MAY EMIT FUMES OF CYANIDE.

===================  Toxicological Information	===================

Toxicological Information:CHROMIC ACID: RAT-ORAL-LD50 ? 80 MG/KG 
    POTASSIUM FERRICYANIDE RAT- ORAL ?1600 MG/KG  ORAL LD50 MOUSE: 2970
    MG/KG  HYDROGEN FLUORIDE (7554-35-3)  INHALATION LC50 MOUSE: 342
    PPM/1H  INHALATION LC50 RAT : 1276 PPM/1H  HYDROGEN FLUORIDE
    (7664-39-3) NOT CLASSIFY AS A HUMAN CARCINOGEN (ACGIH)  CHROMIUM
    ACID (7738-94-5) A1 CONFIRMED HUMAN CARCINOGEN (ACGIH) OCCUPATIONAL
    CARCINOGEN (NIOSH) MONOGRAPH 49: 1 990 (IARC) MUTAGENCITY: NO
    INFORMATION AVAILABLE FOR THE PRODUCT. CHROMIUM VI COMPOUNDS HAVE
    BEEN MUTAGENIC IN BACTERIA, CAUSED CHROMOSOME ABARATIONS CELLS AND
    HEVE BEEN ASSOCIATED WITH INCREASED FREQ UENCIES OF CHROMOSOME
    ABBERRATIONS.

=====================  Ecological Information  =====================

Ecological:NO DATA AVILABLE FOR THIS PRODUCT. BECAUSE OF THE LOW PH OF
    THIS PRODUCT. IT WOULD BE EXPECTED TO PRODUCE SIGNIFICANT
    ECOTOXICITY UPON EXPOSURE TO AQUATIC ORGANISMS AND AQUATIC SYSTEMS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF WASTE MATERIAL ACCORDING TO LOCAL,
    STATE, FEDERAL, AND PROVINCIAL ENVIRONMENTAL REGULATIONS.
    NEUTRALIZE THE SPILLED MATERIAL BEFORE DISPOSAL.

===================  MSDS Transport Information  ===================

Transport Information:DOT SHIPPING NAME: NOT DOT REGULATED.   CONTAINS
    CLAUSE: N/A.   UN / NA NUMBER: N/A.   CLASS: N/A.	PACKAGING
    GROUP: N/A.   PRODUCT RQ (LBS): N/A.   RQ CLAUSE: N/A.   NOTE: RQ
    INFORMATION IS BASED ON  A 55-GAL CONTAINER SIZE. PLEASE REFER TO
    THE PRODUCT LABEL FOR RQ ON OTHER SIZE CONTAINERS.

=====================  Regulatory Information  =====================

SARA Title III Information:THIS MATERIAL CONTAINS ONE OR MORE OF THE
    FOLLOWING CHEMICALS REQUIRES TO BE IDENTIFIED UNDER SARA SECTION
    302 (40 CFR 355 APPENDIX A), SARA SECTION 313 (40 CFR 372.65)
    AND/OR CERCLA (40 CFR302.4). HY DROGEN FLUORIDE 7664-39-3, CHROMIC
    ACID 7738-94-5.
Federal Regulatory Information:POTASSIUM FERRIOYANDE 13746-66-2,
    HYDROGEN FLUORIDE 7664-39-3,  CHROMIC ACID 7738-94-5.
State Regulatory Information:WARNING! THIS PRODUCT CONTAINS A CHEMICAL
    KNOWN O THE STATE OF CALIFORNIA TO CAUSE CANCER.  POTASSIUM
    FERRIOYANIDE 13746-66-2. HYDROGEN FLUORIDE 7664-38-3. CHROMIC ACID.
    7738-94-5.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.