CARBIDE/GRAPHITE GROUP INC -- ACETYLENE -- 6830-00N075023
=====================  Product Identification  =====================

Product ID:ACETYLENE
MSDS Date:08/01/1992
FSC:6830
NIIN:00N075023
=== Responsible Party ===
Company Name:CARBIDE/GRAPHITE GROUP INC
Box:3727
City:LOUISVILLE
State:KY
ZIP:40201-3727
Country:US
Info Phone Num:502-423-4400;800-424-9300(CHEMTREC)
Emergency Phone Num:502-775-4123;800-424-9300(CHEMTREC)
CAGE:CARBX
=== Contractor Identification ===
Company Name:CARBIDE/GRAPHITE GROUP INC
Box:3727
City:LOUISVILLE
State:KY
ZIP:40201-3727
Country:US
Phone:502-423-4400;800-424-9300(CHEMTREC)
CAGE:CARBX

=============  Composition/Information on Ingredients  =============

Ingred Name:ACETYLENE
CAS:74-86-2
RTECS #:AO9600000
Fraction by Wt: >98%
OSHA PEL:N/K 
ACGIH TLV:ASPHYXIANT

Ingred Name:IMPURITIES; (TRACE IMPURITIES) (CONTAINING INGS 3 & 4)
Fraction by Wt: 1-2%
Other REC Limits:2500 PPM (MFR)
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:HYDROGEN SULFIDE (SARA 302/313) (CERCLA)
CAS:7783-06-4
RTECS #:MX1225000
OSHA PEL:20 PPM, C
ACGIH TLV:10 PPM;15 STEL
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:AMMONIA (SARA 302/313) (CERCLA)
CAS:7664-41-7
RTECS #:BO0875000
OSHA PEL:50 PPM
ACGIH TLV:25 PPM;35 STEL
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ASPHYXIANT HAVING ANESTHETIC
    PROPERTIES. ACUTE:SLIGHT INTOXICATION AT 10%. MARKED INTOXICATION
    AT 20%. AT 35% CAUSES UNCONSCIOUSNESS IN 5 MINUTES.
    CHRONIC:CONTAMINANTS IN GENERATED ACETYLENE CAN HAVE  TOXIC EFFECT;
    VIA PHOSPHINE, ARSINE, HYDROGEN SULFIDE. ACETYLENE IS A SIMPLE
    ASPHYXIANT & ANESTHETIC. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:NON-IRRITATING TO SKIN AND MUCOUS
    MEMBRANES.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD IMMEDIATELY . EYES:IMMEDIATELY FLUSH W/POTABLE
    WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM MD .
    SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD . INHAL:REMO VE
    IMMEDIATELY TO UNCONTAMINATED AIR. IF BREATHING HAS STOPPED,
    ARTIFICIAL RESPIRATION SHOULD BE APPLIED. CONSULT MD.

=====================  Fire Fighting Measures  =====================

Lower Limits:2.5%
Upper Limits:82%
Extinguishing Media:EXTING FIRE BY SHUTTING OFF SOURCE OF ACETYLENE.
    FIRES FROM SM LEAKS IN CNTNRS CAN BE EXTING BY PLUGGING LEAK
    W/(SUPDAT)
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT . USE WATER TO COOL FIRE-EXPOSED CYLINDERS.
Unusual Fire/Explosion Hazard:IN MIXTURES CONTAINING MORE THAN 6%
    OXYGEN, MAY BE A MODERATE EXPLOSION HAZARD. GASEOUS AT ROOM
    TEMPERATURE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WARNING! DO NOT ENTER AREA OF HIGH CONC UNTIL
    FIRST PURGING W/NITROGEN & THEN VENTILATING W/AIR. ELIMINATE ALL
    SOURCES OF IGNITION, KEEP PERSONNEL. AWAY. ALL LEAKS OF ACETYLENE
    PRESENT GREAT DANGER OF  EXPLOSION OR FIRE!
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN WELL VENTED AREA, AWAY FROM
    OXYG/NON-FLAMM COMPRESSED GAS CYLS. SHOULD NOT BE PRESSURIZED >15
    PSIG. KEEP CYLS UPRIGHT! FLAMMABLE GAS.
Other Precautions:AVOID SUDDEN SHOCK & ALL SOURCES OF IGNIT INCL STATIC
    ELEC. DO NOT STORE NEAR BRASS CNTNG 60% OR GREATER COPPER. IN
    PRESENCE OF WET ACETYLENE & AMMONIA THIS REACTS TO FORM EXPLO
    ACETYLIDES. SHOULD NOT  BE W/DRAWN AT RATE >1/7 OF CYL (SUPDAT)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH APPROVED SELF-CONTAINED BREATHING
    APPARATUS FOR EMERGENCY WORK AT HIGH CONCENTRATIONS.
Ventilation:KEEP CONCENTRATION <2500 PPM. LOCAL EXHAUST:YES (CUTTING &
    WELDING). MECHANICAL(GENERAL):YES. SPECIAL:EXPLOSION-PROOF.
Protective Gloves:LEATHER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS (SUPP DATA)
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
    SHOWER . ALL COTTON TO PVNT STATIC BUILD-UP WHILE HNDLG CNTNRS.
    (SUPP DATA)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXTING MEDIA:PUTTY/SMOTHERING W/FIRE BLANKET. OTHER PREC:CAPACITY PER
    HR. FASTER WITHDRAWAL MAY CARRY OVER ACETONE/MAY CAUSE STATIC
    SPARKS. EYE PROT:GOGGS , W/FILTER LENS, SHADE #4 OR DARKER WHE N
    WELDING/CUTTING. OTHER PROT EQUIP:FLAME RETARDANT FOR WELDING,
    CUTTING OR BRAZING.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:-103F,-75C
Vapor Density:0.91
Solubility in Water:1.1 G/ML AT 15.5C
Appearance and Odor:COLORLESS, GARLIC-LIKE ODOR FROM IMPURITIES.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
FORMS EXPLO ACETYLIDES W/COPPER, SILVER, MERCURY. MIXED W/CHLORINE OR
    FLUORINE, CAN EXPLODE ON EXPOS TO SUNLIGHT.
Stability Condition to Avoid:UNSTABLE IN FREE STATE UNDER PRESSURE.
    STABLE <5 PSIG OR IN ACETONE SOLUTION.
Hazardous Decomposition Products:UNDER PRESSURE MAY DECOMPOSE INTO
    HYDROGEN & CARBON W/EXPLOSIVE FORCE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
    REGULATIONS . IF PRACTICAL, REMOVE CYLINDER TO SAFE, OUTSIDE AREA.
    VENT TO ATMOSPHERE AT SLOW RATE. KEEP ALL SOURCES OF IGNITION AWAY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.